%PDF-1.5 % ZZY)R! The GreaseTrooper is a gravity grease interceptor (GGI) designed to reduce the amount of FOG (fats, oils, and greases) in wastewater. 425 0 obj <> endobj hbbd```b``"A$"ESA0:@o hbHG DL hX <2[ / endstream endobj startxref 0 %%EOF 85 0 obj <>stream Lard and other high-viscosity fats can also solidify as they cool down, trapping other solids and blocking sewage pipes. of Environmental Protection. The waste discharge from these facilities usually contains hightemperature water, high organic loads, FOG, suspended food particles, and detergents. 612-GGI-2500 Grease Interceptor 2,500 Gal. Ferris, TX 75125 endstream endobj 426 0 obj <. Grease interceptor above ground installation Champion Plumbing 38K views 3 years ago Drain Pros Ep. The interceptor must be cleaned whenever 25 percent of any chamber becomes filled with FOG or solids. P: 713-937-7602Toll Free: 888-611-7275, 8491 Hwy 87 EastSan Antonio, TX 78263P: 210-227-7275, 1200 N Fwy Service Rd Table I requires 14 lb of retaining capacity, Table II requires 20 lb of retaining capacity. Highstrength precast concrete, steel, or fiberglass, Precast concrete, fiberglass, or stainless steel construction, Interior liners include epoxy, high density polyethylene, and stainless steel, Free-standing and direct-bury configurations, Los Angeles, Long Beach, Anaheim, CA - Grease Interceptor GT-500, Austin, Round Rock, Georgetown, Pflugerville, TX - Grease, Wichita Falls, Iowa Park, Burkburnett, TX - Grease Interceptor GT-, San Diego, San Bernadino, Highland, FEWD Program, Carlsbad, CA -, Oceanside, Vista, San Marcos, CA - Grease Interceptor. On-the-floor installation - G Series Of course, there are also cases where the use of grease interceptors is obvious. Some dishwashers have lower waste openings than illustrated on the separators. If these values are exceeded, the grease interceptor capacity must be calculated by an NYC Registered Design Professional, based on data extrapolation. Up and Down arrows will open main level menus and toggle through sub tier links. Gravity Grease Interceptors (GGI), also commonly known as a grease trap, work on the buoyancy principle. 441 0 obj <>/Filter/FlateDecode/ID[<2699F7281AEA5C4E9D5F13A8D243EA86><15504ED7A2B8C8499534A37D03AF58DB>]/Index[425 30]/Info 424 0 R/Length 92/Prev 293128/Root 426 0 R/Size 455/Type/XRef/W[1 3 1]>>stream Animal fats and vegetable oils (grease) are 10 to 15 percent less dense than water and will float on top of water. %PDF-1.3 % Grease interceptors can also have strainers for collecting solid debris, which reduce the amount of solids that settle at the bottom of the interceptor. Using a pot scrubber with soap and room temperature water, remove excess waste from the lid and trap sides. Grease interceptors are used in restaurants and other facilities. Grease Interceptors and How to Maintain Them | Portland.gov On a dishwasher with three tanks, bypass the final rinse cycle when permitted by code. Subscribe to the NY Engineers Blog below. 3 0 obj ^\kmtv\(iz~Rd;1pK]>KG@XXCno r!VtaM'N]eM#aM" wDn6"DY O;(hH|1 15EL:Snf&0iSJ4hll[q.FXn?a20I' VX J MvX=GmM dhJ]9G"r>q,O&t5(4hl-EU6F> yhhTfc4(p sR-|I x*sL!,@G =6 QpH GH'@E9FUH! Do not install the grease interceptor in a waste line from a garbage grinder. << /Predictor 1 For calculation of grease interceptor retaining capacity, the NYC Department of Environmental Protection provides two tables, each with interceptor capacity values (in pounds) corresponding to aggregate volume from kitchen fixtures (in cubic inches). >> ?h_ Ode'3|y 4!f/?[f endstream endobj 72 0 obj 158 endobj 31 0 obj << /Type /Page /Parent 17 0 R /Resources 32 0 R /Contents [ 45 0 R 47 0 R 49 0 R 51 0 R 53 0 R 55 0 R 57 0 R 59 0 R ] /MediaBox [ 0 0 612 783 ] /CropBox [ 0 0 612 783 ] /Rotate 0 >> endobj 32 0 obj << /ProcSet [ /PDF /Text ] /Font << /F2 43 0 R /F3 40 0 R /F4 36 0 R /F5 33 0 R /F6 42 0 R >> /ExtGState << /GS1 63 0 R /GS2 64 0 R >> /ColorSpace << /DefaultCMYK 41 0 R /Cs9 41 0 R >> /Properties << /MC1 68 0 R /MC2 69 0 R /MC3 70 0 R >> >> endobj 33 0 obj << /Type /Font /Subtype /Type1 /FirstChar 32 /LastChar 240 /Widths [ 240 258 407 480 480 759 556 240 241 241 352 600 240 352 240 278 480 480 480 480 480 480 480 480 480 480 240 240 600 600 600 444 800 500 519 519 556 463 444 537 537 204 426 500 444 704 556 556 481 556 519 500 463 519 462 722 481 462 463 259 278 259 600 500 204 444 463 426 463 444 259 463 463 204 204 444 204 722 463 444 463 463 296 407 259 463 406 648 406 406 389 259 222 259 600 240 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 480 480 0 0 0 0 0 800 0 0 0 240 0 0 240 600 240 240 0 463 240 240 240 240 240 0 0 240 0 0 0 0 0 240 0 240 240 0 0 0 240 0 0 0 0 0 0 0 407 407 0 240 0 240 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 240 ] /Encoding /MacRomanEncoding /BaseFont /MIJNKO+HelveticaNeue-Condensed /FontDescriptor 35 0 R >> endobj 34 0 obj << /Type /FontDescriptor /Ascent 714 /CapHeight 714 /Descent -176 /Flags 262240 /FontBBox [ -171 -224 1116 961 ] /FontName /MIJNJJ+HelveticaNeue-BoldCondObl /ItalicAngle -12 /StemV 138 /XHeight 538 /CharSet (/Z/T/C/R/D/S/G/U/I/space/L/M/P/N/O/B) /FontFile3 66 0 R >> endobj 35 0 obj << /Type /FontDescriptor /Ascent 714 /CapHeight 714 /Descent -176 /Flags 32 /FontBBox [ -164 -212 1000 932 ] /FontName /MIJNKO+HelveticaNeue-Condensed /ItalicAngle 0 /StemV 84 /XHeight 536 /CharSet (/quoteright/m/two/three/o/parenleft/p/a/S/parenright/quotedblleft/four/q\ /five/U/N/B/asterisk/r/T/space/b/V/C/six/seven/s/W/c/d/D/comma/F/t/eight\ /e/E/G/hyphen/u/quotedblright/nine/f/P/I/n/numbersign/v/period/Z/colon/h\ /x/w/slash/i/L/y/zero/j/M/z/g/l/one/k/O/A) /FontFile3 62 0 R >> endobj 36 0 obj << /Type /Font /Subtype /Type1 /FirstChar 32 /LastChar 181 /Widths [ 240 296 463 480 480 778 593 260 296 296 390 600 240 370 240 332 480 480 480 480 480 480 480 480 480 480 240 240 600 600 600 481 800 556 556 537 574 481 463 556 556 258 463 537 463 740 574 556 519 556 556 519 480 538 519 760 537 520 481 315 332 315 600 500 222 481 500 463 500 463 296 500 500 240 240 500 240 758 500 480 500 500 333 444 296 500 444 704 462 444 426 315 222 315 600 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 480 480 240 240 240 240 240 800 240 240 240 240 240 240 240 600 240 240 240 500 ] /Encoding /WinAnsiEncoding /BaseFont /MIJNJJ+HelveticaNeue-BoldCondObl /FontDescriptor 34 0 R >> endobj 37 0 obj << /Type /FontDescriptor /Ascent 714 /CapHeight 714 /Descent -176 /Flags 262176 /FontBBox [ -164 -224 1066 961 ] /FontName /MIJNMB+HelveticaNeue-BoldCond /ItalicAngle 0 /StemV 138 /XHeight 538 /CharSet (/quoteright/m/two/three/o/parenleft/R/p/a/S/parenright/four/five/quotele\ ft/U/N/K/B/r/T/space/V/six/C/s/seven/W/d/F/D/comma/c/t/eight/X/e/E/G/hyp\ hen/u/f/P/I/n/Z/h/colon/w/slash/i/L/H/zero/M/z/g/l/one/O/A) /FontFile3 60 0 R >> endobj 38 0 obj << /Type /FontDescriptor /Ascent 714 /CapHeight 714 /Descent -176 /Flags 96 /FontBBox [ -171 -212 1068 932 ] /FontName /MIJNJL+HelveticaNeue-CondensedObl /ItalicAngle -12 /StemV 84 /XHeight 536 /CharSet (/two/T/colon/m/C/w/o/R/F/D/comma/c/four/S/E/G/hyphen/z/five/U/I/A/n/peri\ od/six/space/V/r/slash/seven/W/H/eight/zero/X/u/one/nine/P/O/N/B) /FontFile3 67 0 R >> endobj 39 0 obj << /Type /FontDescriptor /Ascent 714 /CapHeight 714 /Descent -176 /Flags 262240 /FontBBox [ -172 -230 1148 972 ] /FontName /MIJNIH+HelveticaNeue-BlackCondObl /ItalicAngle -12 /StemV 180 /XHeight 541 /CharSet (/T/C/R/E/S/G/I/A/space/P/N/O) /FontFile3 61 0 R >> endobj 40 0 obj << /Type /Font /Subtype /Type1 /FirstChar 32 /LastChar 240 /Widths [ 240 296 463 480 480 778 593 260 296 296 390 600 240 370 240 332 480 480 480 480 480 480 480 480 480 480 240 240 600 600 600 481 800 556 556 537 574 481 463 556 556 258 463 537 463 740 574 556 519 556 556 519 480 538 519 760 537 520 481 315 332 315 600 500 222 481 500 463 500 463 296 500 500 240 240 500 240 758 500 480 500 500 333 444 296 500 444 704 462 444 426 315 222 315 600 240 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 480 480 0 0 0 0 0 800 0 0 0 240 0 0 240 600 240 240 0 500 240 240 240 240 240 0 0 240 0 0 0 0 0 240 0 240 240 0 0 0 240 0 0 0 0 0 0 0 0 0 260 260 0 240 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 240 ] /Encoding /MacRomanEncoding /BaseFont /MIJNMB+HelveticaNeue-BoldCond /FontDescriptor 37 0 R >> endobj 41 0 obj [ /ICCBased 65 0 R ] endobj 42 0 obj << /Type /Font /Subtype /Type1 /FirstChar 32 /LastChar 181 /Widths [ 240 258 407 480 480 759 556 240 241 241 352 600 240 352 240 278 480 480 480 480 480 480 480 480 480 480 240 240 600 600 600 444 800 500 519 519 556 463 444 537 537 204 426 500 444 704 556 556 481 556 519 500 463 519 462 722 481 462 463 259 278 259 600 500 204 444 463 426 463 444 259 463 463 204 204 444 204 722 463 444 463 463 296 407 259 463 406 648 406 406 389 259 222 259 600 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 480 480 240 240 240 240 240 800 240 240 240 240 240 240 240 600 240 240 240 463 ] /Encoding /WinAnsiEncoding /BaseFont /MIJNJL+HelveticaNeue-CondensedObl /FontDescriptor 38 0 R >> endobj 43 0 obj << /Type /Font /Subtype /Type1 /FirstChar 32 /LastChar 181 /Widths [ 260 314 481 520 520 778 611 260 314 314 406 600 260 368 260 333 520 520 520 520 520 520 520 520 520 520 260 260 600 600 600 500 800 556 574 537 574 500 481 556 574 260 481 556 463 758 592 556 537 556 574 537 462 556 520 778 536 520 481 314 333 314 600 500 260 500 520 481 520 481 315 520 520 258 258 500 258 778 520 500 520 520 352 463 315 520 463 740 481 463 444 333 222 333 600 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 520 520 260 260 260 260 260 800 260 260 260 260 260 260 260 600 260 260 260 520 ] /Encoding /WinAnsiEncoding /BaseFont /MIJNIH+HelveticaNeue-BlackCondObl /FontDescriptor 39 0 R >> endobj 44 0 obj 19558 endobj 45 0 obj << /Filter /FlateDecode /Length 44 0 R >> stream An example is the Blakeslee dishwasher with a 3 center line waste outlet and with the new dry recirculating pump which requires that the static water level in the separator be lower than 9. Please avoid adding links in comments. The retaining capacity is calculated separately for the fixtures in each table and the two values are then added. 0=>p[0 ! )GRGN Our design and manufacturing capabilities offer client focused solutions to meet the growing demands and regulatory requirements of the water industry. cHl a4 3030`\ (|0bE^lRL)/8 U? a#7\*S$S`Rn3aH#{`hf08ClpM9 by\J#'Tm5v"s'. If multiple grease traps are used, the procedure is carried out separately for each one. This ensures code compliance, offers hygiene for your staff and customers, and prevents the uncontrolled discharge of grease and oil into the environment. GB-75 | Indoor/Outdoor Hydromechanical Grease Interceptor - Schier Products Using manual valves to reduce flow to a grease interceptor is not allowed. Flush-with-floor installation GIS Serieswith body vent, Flush-with-floor installation GF & GFESeries with body vent. Most local plumbing codes prohibit any industrial user from discharging FOG over 100 mg/l into the public sewer system. Mesa Standard Details & Specifications | City of Mesa - Mesa, Arizona For more details on installation and maintenance go to WWW.PDIONLINE.ORG . % Precast concrete grease interceptor tanks are guaranteed water tight and are vacuum tested on-site after installation. The accumulation of FOG can escalate into blockages and sanitary sewer overflows (SSO) that disrupt wastewater treatment operations and increase costs. Plumbing & Drainage Institute - PDI Certified Grease Interceptors <> Sizing - PDI Method Using Sink Dimensions. By working with qualified design engineers, you can ensure your grease traps are specified properly. 20GPM GREASE INTERCEPTOR 2"SPG. The retained FOG should be regularly removed or pumped out of the interceptor. Protect waste lines against blocking and stoppages. Animal fats and vegetable oils (grease) are 10 to 15 percent less dense than water and will float on top of water. Grease Trap Pit is a precipitation system designed to trap grease and suspended sediment in industrial wastewater. Gravity Grease Interceptors (GGI), also commonly known as a grease trap, work on the buoyancy principle. Install outlet tee with 6" diameter vertical riser. With these values. Web grease interceptor sizing and installation guidelines. Specify M (Outlet opposite Inlet), L (Left Hand Outlet), or R (Right Hand Outlet) on your order. Grease Interceptors | Oldcastle Infrastructure Hydromechanical grease interceptors (HGI) (sometimes called grease traps) are installed indoors above or below the floor, or inground outside. Phone: 419-836-2300. NOTE: All PDI certified grease interceptors are required to bear a PDI issued Certification Plate, as depicted, containing permanent marking of: Manufacturer's Name; Model Number; Flow Rate; Inlet Size; Grease Capacity; and appear in the listings below. GB-50 | Indoor/Outdoor Hydromechanical Grease Interceptor - Schier Products The tables can be viewed directly in the. 4800 Install 10-2017 . However, wastewater from food preparation contains more oil than in other applications, and the waste from multiple commercial kitchens can overwhelm water treatment systems and cause spillage. 3. Reinstall the grease trap. For projects in New York City, only a Registered Design Professional (RDP) can submit. A certain oil content is normal in wastewater, and it forms a thin floating layer once it reaches septic tanks and water treatment facilities. Oldcastle Infrastructures grease interceptors are manufactured in a variety of standard and custom sizes. SIDE VIEW DETAIL INSTALLATION (1 of 2) page 3 of 5 WARNING! Interceptor shall be . This value applies if all the kitchen fixtures in the example discharge into a common interceptor. PGIs are designed to remove large quantities of sewer-clogging fats, oils, and grease before it's discharged into a municipal wastewater treatment system. US $51.30. Precast concrete interceptors shall conform to the . Installation Detail - Golf with Pad Board/Curb Download DWG. Model #GB-250-FO 100 GPM Grease Interceptor For Indoor/Outdoor Use . older versions (Use only for reference for previously approved projects). Side connections are prohibited for inlet or outlet. Supplied with accessible flow control device (HxHxH) for solvent weld . Over time, solid and grease buildup will accumulate in the grease interceptor. Grease Trap - Free CAD Block And AutoCAD Drawing NYC Dept. Although the procedure is straightforward, keep in mind that some exceptions apply: A final requirement is that water flowing through a grease interceptor must not have a temperature above 180F. M.A.G. jK^fg)b+"eDDdc$D(86ME"E$X$:%%""hLn_U=g#/xK/Z#>AU,(>44M;t?3l/ww/e5~,b.dE18 {JEgwsQy'|8R>1Y -D/tF=zC't@O/*M~]MS_RI~+P:TSFsZ>5Ti}f~})TJ"nV{{b'p|VA8q?p3U1mV^y]x!iIQ;VReUy+}M__k;#fD With an internal flow control, an external flow control is not necessary. Core drill all penetrations in vault. Trapping and Venting for Grease Interceptors - IWConsultingService Passive grease interceptors help food service establishments and food processing industries comply with EPA Sewer Pretreatment Regulations. In general, grease traps contain baffles with baffles. For example, scullery sinks and meat preparation sinks produce large amounts of grease, oils and solids. PDF Grease Interceptor Sizing and Installation Guidelines - Tacoma Permits 1 0 obj Clean the trap sides, lids, and parts. CU?E?W*Ut3>~ %PDF-1.5 Grease Interceptor Sizing and Installation Guidelines Next, use water to flush the parts and screens in order to get rid of debris and soap. 4 0 obj Over 15 years field proven performance has bean lead by the Endura. Installation is a breeze. Adjustment should be checked after Interceptor is in operation. 6. 816-GGI-5000 Grease Interceptor 5,000 Gal. Cleaning (5000 and 5100 Series) The frequency of cleaning is determined by the use load factor and the capacity of the installed interceptor. It can be installed above grade (on the ground) or buried below grade (compatible with FCR2 riser to bring system to grade), as well as indoor or outdoor. Installation of Grease Interceptors. shown in Detail "A". Tab will move on to the next part of the site rather than go through menu items. Product Information. %PDF-1.5 % They are used to train mechanics, hotels, supermarkets and other Toilet Installation January 19, 2018 The tables can be viewed directly in the NYC Dept. for approval by the NYC Department of Buildings, and only a Licensed Master Plumber (LMP) can carry out the actual installation. endobj 7. Concrete Grease Interceptor Tanks Tanks are reinforced and constructed to ASTM Standards to include C-1613-06. Consult local codes for separate trapping requirements, cleanout locations and additional installation instructions. Also referred to as grease traps or grease recovery devices, our grease interceptors are designed for storage of greases/oils as well as solids before entering a wastewater disposal system. Installation Diagrams - Rockford Separators Grease interceptors should be installed for any commercial kitchen equipment where grease may be released into drain pipes. SCHIER GB-50 INSTALLATION MANUAL Pdf Download | ManualsLib PDF TABLE OF CONTENTS - Watts }2U;OgC/VY;pHo4|lQ? Gravity Grease Interceptor Design - Precast Title: Grease Interceptor Layout1 (1) Author: christw Created Date: 1/16/2013 1:38:41 PM 4800 series. DO NOT AIR TEST UNIT OR TELEGLIDE RISER SYSTEM! 75 GPM Hydromechanical Grease Interceptor. Cleaning and grease removal must a part of routine maintenance, and the units should be accessible for inspection by the NYC Dept. PDF Procedures for Design, Construction and Installation of Interceptors Standard Details | Johnson County Kansas PDF Operation, Installation and Maintenance Instructions 5000-5100 Series The GB-75 offers best-in-class certified grease capacity and 25% kitchen solids waste capacity. P: 972-842-8801, Kimberly JenkinsAtlanta, GAP: 706-506-2805, Impact of Flushable Wipes on Wastewater Treatment. Please take a moment to complete a short survey to provide your input, *For older versions of the Mesa Standard Details and Specifications please contact Engineering-Admin@MesaAZ.gov, M.A.G. US $54.00. Volume-Based Grease Interceptors. Enter and space open menus and escape closes them as well. PDI G101 mandates the installation of an vented external flow control. Jensen Precast - Gravity Grease Interceptors - Standard Grease Interceptor Installation Inspections Partial Inspection #1: JCW inspection of the excavation, interceptor, riser (s) and anchor kit (if applicable) is required prior to backfill. Solidified grease can cause stoppages downstream in piping systems and create costly and time-consuming problems at municipal wastewater treatment plants. Each compartment, 18 inches by 18 inches by 8 inches with 1.5-inch sink drain and trap. As the waste stream flows through the orifice in the flow control device negative pressure is created, drawing in air from the air intake which is intended to mix with the waste water as it enters the grease interceptor aiding in separation efficiency. The use of alternative devices is allowed, as long as the following requirements are met: Grease interceptors perform a fundamental role in commercial kitchens, as well as other applications where significant amounts of grease or oil are discharged. A good product can have poor performance if it used in the wrong application or installed incorrectly. Call 1-800-541-8004 for more information . stream When wastewater enters a grease interceptor, the velocity is reduced enough that wastewater is given time to cool and separate into 3 layers. PDI-G101: Testing and Rating Procedure for Hydro Mechanical Grease Interceptors (Plumbing and Drainage Institute), ASME A112.14.3: Grease Interceptors (American Society of Mechanical Engineers), After a grease interceptor layout has been proposed, the next step is calculating the. PDF Guidance Document for Sizing and Installation of Grease Traps and ANCHOR KIT INSTALLATION DETAIL 2-1/2" Minimum Insertion Depth 4" Maximum Insertion Depth (into GB unit only) FIELD CUT RISER (24 SERIES) INSTALLATION GUIDELINES Tools needed: 7/16" Nut driver tool/bit (included), marker (included), tape
Muscogee Creek Nation Camphouse Portal Login, Things To Do In Chittenden County Vt, Rcc Financial Aid Disbursement Spring 2022, Texas Longhorns 1998 Football Depth Chart, Petition For Writ Of Mandate California Superior Court, Articles G